Impression post 5.3 mm for closed impression, Hex Connection incl. screw blue + transfer cap

Advantages

  • color-coded in line with the implant diameter
  • equipped with a fixing screw and transfer cover

Properties

  • Closed Impression Technique

Description

Closed Impression Technique

Product number: 638869
Questions about the product? We are glad to be here for you!
Product information "Impression post 5.3 mm for closed impression, Hex Connection incl. screw blue + transfer cap"

Closed Impression Technique

The IMPLA impression posts are color-coded in line with the implant diameter and equipped with a transfer cover and vertical screw. A preassembled impression tray can be used for the closed tray impression technique. To secure the impression post in place, the vertical screw should be carefully hand-tightened both in the implant and on the laboratory implant using the 1.2 mm screwdriver. The transfer cover (repositioning aid) is pushed onto the impression posts until a noticeable pressure point is overcome and the transfer cover is clearly secure.

"
Brochures and further information on this product

Cutsomers also bought

Lab implant 5.3 mm,
Screws in with the Hex Connection impression aid or the Hex Connection impression post, facilitating precise model production.
Details
Impression post 3.3 mm for closed impression, Hex Connection incl. screw blue + transfer cap
Closed Impression Technique The IMPLA impression posts are color-coded in line with the implant diameter and equipped with a transfer cover and vertical screw. A preassembled impression tray can be used for the closed tray impression technique. To secure the impression post in place, the vertical screw should be carefully hand-tightened both in the implant and on the laboratory implant using the 1.2 mm screwdriver. The transfer cover (repositioning aid) is pushed onto the impression posts until a noticeable pressure point is overcome and the transfer cover is clearly secure. equipped with a fixing screw (art. no. 636658) and transfer cover (art. no. 635495) "
Details
Impression post 4.2 mm for closed impression, Hex Connection incl. screw blue + transfer cap
Closed Impression Technique The IMPLA impression posts are color-coded in line with the implant diameter and equipped with a transfer cover and vertical screw. A preassembled impression tray can be used for the closed tray impression technique. To secure the impression post in place, the vertical screw should be carefully hand-tightened both in the implant and on the laboratory implant using the 1.2 mm screwdriver. The transfer cover (repositioning aid) is pushed onto the impression posts until a noticeable pressure point is overcome and the transfer cover is clearly secure. equipped with a fixing screw (art. no. 636658) and transfer cover (art. no. 635495) "
Details