Impression post 3.3 mm for closed impression, Hex Connection incl. screw blue + transfer cap

Advantages

  • color-coded in line with the implant diameter
  • equipped with a fixing screw and transfer cover

Properties

  • Closed Impression Technique

Description

Closed Impression Technique

Product number: 638867
Product information "Impression post 3.3 mm for closed impression, Hex Connection incl. screw blue + transfer cap"

Closed Impression Technique

The IMPLA impression posts are color-coded in line with the implant diameter and equipped with a transfer cover and vertical screw. A preassembled impression tray can be used for the closed tray impression technique. To secure the impression post in place, the vertical screw should be carefully hand-tightened both in the implant and on the laboratory implant using the 1.2 mm screwdriver. The transfer cover (repositioning aid) is pushed onto the impression posts until a noticeable pressure point is overcome and the transfer cover is clearly secure.

"

Cutsomers also bought

Lab implant 3.3 mm,
Screws in with the Hex Connection impression aid or the Hex Connection impression post, facilitating precise model production.
Details