Micro Retention implant 4.2/11.5 mm, sterile, (Hex Connection)

Description

The implant with the basic conical shape and internal hexagonal connection.

Product number: 635276
Product information "Micro Retention implant 4.2/11.5 mm, sterile, (Hex Connection)"

Our Micro-Retention implant is the result of persistent further development of renowned quality. Its specially conceived micro-thread helps it achieve an exceptional degree of primary stability and therefore, safety, even when the bone situation is not favourable, for example in cancellous upper jaw bones, or in the sinus area with reduced residual bone. You also have the option of working with Platform Switching here. The high precision Hex inner connection with rotation protection guarantees a secure connection between implant and abutment.

Benefits:

  • Hex connection for rotation-secure connection between implant and abutment
  • Special micro-thread for very high primary stability
  • Optimised thread design for improved primary stability even in soft bones
  • Integrated Platform Switching to improve the soft tissue attachment
  • Micro-constructed, highly pure surface for optimal cell adaptation and safe osseointegration
Connection: Hex

Accessories

hex screwdriver long, width 1.2,
Variante: 1,2 mm / lang
The required torque for the retaining screw is exerted with the help of the torque ratchet. This long version of the screwdriver can be used in jaws with teeth, in the anterior area. It has a 1.2 mm hexagon at the tip. A drilled hole for a safety cord is located in the turntable of the screwdriver grip.
Details
Depth gauge 3.3mm brown,
Variante: 3,3 mm
For checking the plant implant insertion depth after use of the pilot drill.
Details
Locator lab implant,
For transferring the impression situation to the master model.
Details
ball anchor 4/5.3 mm,
Variante: 4 mm / 5,3 mm
Partial and hybrid prostheses with a 2.25 mm round head. Two different gingival heights 2 mm and 4 mm.
Details
Lab implant 5.3 mm,
Variante: 5,3 mm
Screws in with the Hex Connection impression aid or the Hex Connection impression post, facilitating precise model production.
Details
activator / deactivator,
Using this wrench, the gold inner matrix can be compressed (activated) or expanded to match the position of the prosthesis.
Details
Instrument contra-angle,
Contra angle-driven 3 mm Allen key for insertion post of IMPLA implants for machine insertion. The key has a snap-in function for implants.
Details
Plastic sleeve POM, for Multi Unit
Acrylic sleeve made of POM (polyoxymethylene) for the Multi Unit System, can be burned out.
Details
torque ratchet,
A socket for the different tools, such as screwdrivers and tighteners, is located on the head of the ratchet. It restricts the torque previously set on the tensioning screw - between 0 and 30Ncm - by slipping off the ratchet head. This torque limit can be disabled by twisting the head, in order to tighten implants into the perfect position, for example. The direction of rotation is marked on the ratchet head. We recommend taking the ratchet apart for purposes of cleaning and sterilisation.
Details
Locator matrix set (3 parts),
In the smallest version, the Locator® has a total height of 3.3 mm with a retention housing and nylon insert. ,This makes the Locator® System also suitable in circumstances where vertical space is limited.
Details
parallel positioning aid,
For straight placement of model axes in master models.
Details
Locator plugin, extended range, 4 pcs./green,
Nylon matrix for insertion into the Locator matrix housing. Without centric retention, 20° divergence compensation, shearing force 1.360-1.800 g.
Details
Prosthetic screw secondary, (for Multi Unit Abutment)
This screw is used for the fixation of a restoration on Multi Unit Abutments.
Details
inner matrix yellow/light,
Variante: Gelb / Schwach
If the inner matrix is exchanged during a recall, it can be replaced in seconds by a completely new inner matrix, using a specially made torque wrench. Three color-coded inner matrices with standardized shearing force are available. With existing prostheses where the acrylic inner matrix appears too weak, this can be exchanged for the precious metal inner matrix very easily,without having to change the retention cap!
Details
Module Implantology Tools, assembled, size M
Adapt your IMPLA surgical box according to your individual needs. This compact tray contains all tools necessary for the insertion of an IMPLA Cylindrical or Micro Retention implants. As the tray manages without silicone plugs, it provides for a maximum of hygiene. This tray can be extended optionally.  
Details
Locator plugin, extended range, light retention, 4 pcs./red
Nylon matrix for insertion into the Locator matrix housing. With centric retention, 20° divergence compensation, shearing force 220-680 g.
Details
retention cap, small, for framework stabilization
Various inner matrices can be screwed into the retention cap using this specially made torque wrench. If the inner matrix gets worn out, they can be replaced easily, without having to change the inner matrix.
Details
open-end pick-up,
This open ended wrench is needed for transfer of the implant into the IPK wrench, and insertion via the drilling template. The open ended wrench can also be used for non-contact removal of the implant from the packing, even where the opening of the patient’s mouth is limited (Pick Up technique).
Details
Metal sleeve (for Multi Unit),
Titanium sleeve made from titanium grade 5 - for friction-free glue fixing on abutments of the Multi Unit System.
Details
Locator adapter, with contra-angle connector,
Tool for unscrewing the Locator abutment with contra-angle or as an insert in conjunction with 636077 in the torque ratchet.
Details
Pilot drill 2.0 mm,
Surgical pilot drill without internal cooling for different drill settings during the preparation of the implant site for the IMPLA implant lines Cylindrical, Dual Surface and Micro Retention (according to the drill protocol, limited use for Mini and Interim).
Details
Locator replacement plugin, 4 pcs./clear,
Nylon matrix for insertion into the Locator matrix housing. With centric retention, 10° divergence compensation, shearing force 2.260 g.
Details
key for insertion aid (for ratchet) long, width 3,
Variante: Schlüssel für Eindrehhilfe lang, SW 3
The tool’s working tip fits onto the external hexagon of the insertion post. It can be used by hand, or with the torque ratchet.  This long version of the tightening aid can be used in jaws with teeth, in the anterior area. A drilled hole safety cord is located in the turntable of the grip.
Details
Transfer cap for Mini implant conetop,
By attaching the acrylic cap this locks on cleanly to the impression post or directly onto the connection on the Mini-conetop implant. After a successful impression, the transfer cap remains in the impression and helps fix the corresponding laboratory analogue. The acrylic transfer cap is not suitable for use more than once!
Details
Adhesive base 3.3 mm, CEREC, (for Hex Connection)
Variante: Klebebasis 3,3 mm, CEREC
Produce individual CAD/CAM designed and milled implant abutments and individual tooth restorations on IMPLA implants with the IMPLA adhesive base CAD/CAM CEREC®. Based upon the Sirona CEREC® System.
Details
PreFace Abutment Hex Connection
Variante: 5,3 mm / D = 11,5 mm
Our PreFace®-Abutments facilitate the use of PreFace®-Abutment Holders by Medentika. The PreFace®-Abutments are available in the diameters 11.5 mm and 16 mm and with the connection geometries Hex Connection and Cone Connection. This offers the user the necessary variability. The abutments are made of titanium grade 5 which makes them easy and safe to handle. Titanium grade 5 is also highly biocompatible.Your benefits:With PreFace Abutments® you will achieve a superior added value by flexibility – Use our PreFace®-Abutments together with the PreFace®-Abutment Holders by Medentika. saving time – Two different blank diameters guarantee significantly shorter working times in production. exact definition of the zero position – The uniform length despite the different diameters lets you define the zero position almost exactly. variability – The two different diameters 11.5 mm and 16 mm facilitate flexible work.  precision – The preset production processes as well as the standard production processes provide for even more precise results. Material: Titanium grade 5
Details
model axis,
Stainless steel laboratory analogue for production of models.
Details
Locator impression post,
For transferring the situation in the mouth to the impression.
Details
torque wrench 4 Ncm,
Using this torque wrench the inner matrix is screwed into the matrix housing and set onto the patrix. Inner assembly matrices with blue acrylic inserts should not be used as permanent inner matrices in prostheses, they are intended exclusively for use in the dental laboratory.
Details
adapter ratchet for Locator adapter contra-angle,
Tool for manual unscrewing the Locator abutment in conjunction with 636075 in the torque ratchet.
Details
hex screwdriver long, width 2.3,
Variante: lang
This screwdriver with ratchet connection is a 2.3 mm hex and can be used either in connection with the torque ratchet or manually. The screwdriver 2.3 mm fits directly into the inner hex of the IMPLA Hex implants. It is used to adjust the screw-in depth after removing the insertion post (e.g. to correct the position of the hex). What's more, it serves as a screwdriver for SAE cone adapters. The tool has a hole through which it can be secured with a thread.
Details
Parallelization aid for implants,
This parallelling device is used to check the pilot drilling and to check that the drill holes are parallel. It is also suitable to check the DVT (drilling depth).
Details
Depth stop set,
Variante: Tiefenstopp Set
For an even higher level of safety in implantologyAccessory for IMPLA surgical drills (with suitable drill coil), mechanical depth stop in the jaw bone. Simply attach the depth stop to the drill. Your benefits: Easy handling Safe friction fit Color coding for easily matching the depth stop to the according surgical drill The depth stop is available in three different diameters: narrow (brown), medium (red) and wide (blue). By means of the color coding and the print with the drilling depth on the depth stop, it can be matched easily to the according surgical drill. The depth stops are available in each implant length. The drills can be used with or without the depth stop. Set contains: 5x depth stop narrow / brown: je 1x 6.5 mm, 8.0 mm, 9.5 mm, 11.5 mm, 13.0 mm 5x depth stop medium / red: je 1x 6.5 mm, 8.0 mm, 9.5 mm, 11.5 mm, 13.0 mm 5x depth stop wide / blue: je 1x 6.5 mm, 8.0 mm, 9.5 mm, 11.5 mm, 13.0 mm
Details
Steribox S, empty, A8/ for 1 module
Variante: für 1 Modul
Sterilization box available in sizes S, M and L, for the sterilization of surgical instruments.Dimensions size S (A8):  Outside dimensions: 90 x 90 x 55 mmInternal dimensions: 65 x 60 x 47 mm Dimensions size M (A6): Outside dimensions: 190 x 110 x 60 mmInternal dimensions: 165 x 92 x 49 mm Dimensions size L (A4): Outside dimensions: 290 x 190 x 60 mmInternal dimensions: 265 x 165 x 49 mm Sterisafe® DURO Sterilization container Sterility barrier and packaging system made from high-performance plastics Suited to almost all steam sterilization procedures under vacuum at temperatures of 121°C (249.8 °F) and 134°C (273.2 °F) as well as to low-temperature sterilization with gas (FORM and EO) and to H2O2/H2O2-plasma (in the following: VH2O2). Only tools which are suited to multiple sterilization and to this sterilization procedure must be sterilized in Sterisafe® DURO. Sterisafe® DURO sterilization container made from high-performance plastics: are translucent are highly shock-resistant (no dents) are >, pH 10 reprocessable can be sterilized with steam, plasma, EO or FO. are maintenance-free (no seal, no erosion), upper and lower part of the container close bacteria-proof according to Pasteur's principle are proven to save downtimes and service cost of your instruments have been well-proven for many years Sterisafe® DURO sterilization container have been designed in accordance with national / international standards and regulations DIN EN 868-1 and -8: 1999 DIN EN ISO 11607-1 and -2: 2006 CE marking in accordance with MDD 93/42 EWG
Details
Vertical screw standard, Vertical screw for Impla Direkt GH 1.5 mm
Has a fine thread, which meshes perfectly with the inner thread of the implant, cold welded. This make it practically impossible for the abutment to become loose.
Details
Vertical screw POM,
This vertical screw made of POM facilitates an optimal adhesion at the connection between adhesive base and CAD/CAM element. The perfect fit of the plastic screw reliably prevents adhesive residue from entering the screw channel.
Details
bone thread cutter 5.3 mm,
Variante: 5,3 mm / universal
Precutting the thread reduces the screw-in torque especially in D1 and D2 bone qualities, to avoid overheating and extreme compression. Use the thread cutter considering the drilling protocol for Micro Retention and Dual Surface implants.
Details
Gingiva sleeve PEEK, (for Multi Unit)
PEEK gingiva sleeve for the Multi Unit System, can be adjusted individually.
Details
PreFace Abutment Hex Connection
Variante: 5,3 mm / D = 16 mm
Our PreFace®-Abutments facilitate the use of PreFace®-Abutment Holders by Medentika. The PreFace®-Abutments are available in the diameters 11.5 mm and 16 mm and with the connection geometries Hex Connection and Cone Connection. This offers the user the necessary variability. The abutments are made of titanium grade 5 which makes them easy and safe to handle. Titanium grade 5 is also highly biocompatible.Your benefits:With PreFace Abutments® you will achieve a superior added value by flexibility – Use our PreFace®-Abutments together with the PreFace®-Abutment Holders by Medentika. saving time – Two different blank diameters guarantee significantly shorter working times in production. exact definition of the zero position – The uniform length despite the different diameters lets you define the zero position almost exactly. variability – The two different diameters 11.5 mm and 16 mm facilitate flexible work.  precision – The preset production processes as well as the standard production processes provide for even more precise results. Material: Titanium grade 5
Details
screwdriver width 2.3 mm, machine-driven
The screwdriver with contra-angle connection offers a 2.3 mm hex connector. With help of the contra-angle, it is used to screw in two-piece IMPLA implants automatically and directly. The screwdriver 2.3 mm fits exactly into the inner hex of the IMPLA Hex Connection implants to insert them. Furthermore, it serves as a screw-in instrument for SAE cone adaptors.
Details
Locator abutment, D=5.3 mm GH=2.0,
Variante: 5,3 mm / 2 mm
TiN coated assembly for fixing overdentures. Individual axes on the implant may diverge by max, 20° (10° for implants with Ø 3.3 mm) and between two implants by max. 40° (20° for implants Ø 3.3 mm). ,The self-orienteering construction of the Locator® anchoring system supports the patient when inserting and fixing the prosthesis.
Details
vertical screw blue,
Comes with the implant and helps repeated use when making prostheses in the laboratory. Item no 636649 is strongly recommended as the final connection screw.
Details
Guide key for insertion aid,
Any loosening movement of the implant is prevented by pushing up the outer hexagon on the insertion post when releasing the retaining screw. Furthermore, the insertion post can be loosened if it ever jams.
Details
Fixation screw OT for Multi Unit,
This fixation screw is suited to be used with the forming aid Multi Unit. Due to the knurling at the screw head, this screw is safe and easy to use.
Details
Impression post Multi Unit,
An impression aid for impressions of Multi Unit abutments on abutment level. Fix the impression aid on the Multi Unit abutments with help of the fixation screw OL.
Details
Scan abutment for Multi Unit,
This bowling pin shaped PEEK abutment is excellently suited for digital measuring with optical scanners or laser scanners. The Best Fit-function of the design software is precisely supported by an additional levelled surface.Preparing the scan abutment with scan spray is not necessary, as it is optimally scanned because of its dull whitish color.
Details
Pilot drill 1.2 mm,
The pilot hole created by the marking drill in the bone guides the tip of the pilot drill which follows, and stops it slipping in difficult to reach areas, and in unfavourably shaped jaw ridges. The drill has laser markings matching the implant lengths and so can also be used as a pilot drill.
Details
Gingiva former, cylindrical 4.2/3 mm, sterile,
Variante: 4,2 mm / 3 mm
The cylindrical gingiva former is used to shape the gums after re-opening, or alternatively during transgingival healing. This extends the implant to a ""supra gingival mucous membrane level"". The cylindrical shape is chosen for its delicate emergence profile, particularly with narrow gaps, or where several implants are close together.
Details
Adhesive base D 4.2 mm,
Variante: 4,2 mm
Use this titanium base (titanium grade 5) to glue both individual crowns and bridge constructions made from ZrO2. We recommend the use of Sebond Implant and Alphalink Implant for this procedure.
Details
retention cap, large, for resin curing, for resin curing
Various inner matrices can be screwed into the retention cap using this specially made torque wrench. If the inner matrix gets worn out, they can be replaced easily, without having to change the inner matrix.
Details
Locator instrument, three-part,
Screwed stainless steel tip for removing retention inserts, mid section for repositioning the retention inserts, and gold coloured insertion aid for final screwing of the Locator®.
Details
Universal Drilling Guide,
The Universal Drilling Guide is a drilling aid and supports you when inserting the distal implants: Pilot drilling mesial without angulation. Starting from this situation you can align the implants with help of the Universal Drilling Guide in 0°, 20° and 30°. The Universal Drilling Guide is especially well suited for the Multi Unit System.
Details
Acrylic abutment 0°/3.3 mm,
Variante: 3,3 mm
This material which burns out with nearly no residue is especially well suited for the production of individual abutments by carving or casting. The acrylic abutment bonds well to most carving waxes and acrylics used in a dental lab. This brings clean casting results and an excellent fit of the restorations you produce. Thanks to the very precisely manufactured hex connections of the acrylic abutments, they are highly protected from rotation..Indications: • bar-supported restorations• individual crowns• bridges
Details
Locator plugin, light retention, 4 pcs./pink,
Nylon matrix for insertion into the Locator matrix housing. With centric retention, 10° divergence compensation, shearing force 1.360 g.
Details
bar screw,
Connection screw for constructions on cone adapters, ensures permanent fixing of the supra construction on the cone adapter, as well as the bar and the screwed bridge construction, also with the SAE technique. ,
Details
contra-angle adapter width 1.2 mm short,
Variante: 1,2 mm / kurz
This can be used either manually (adapter for elbow instruments 636077) or with the elbow attachment. The short version is used for jaws without teeth, or in cases where the mouth opening is limited. It has a 1.2 mm hexagon at the tip.
Details
Scanabutment 3,3mm,
Variante: 3,3 mm
Abutment for digital scanning of model situations on the master model. For IMPLA hex connection. This PEEK abutment is especially well-suited for digital measuring with optical scanners or laser scanners due to its bowling pin shape. The Best Fit-Function of the design software is excellently supported by means of a flat surface. The scan abutment does not need to be prepared with scan spray, as the scanner will easily capture it due to its whitish matt color. Your benefits: Extraordinary digital measuring due to the bowling pin shape No preparation with scan spray necessary Size easily recognized because of laser markings Made in Germany
Details
Locator plugin, extra light retention 4 pcs./blue,
Nylon matrix for insertion into the Locator matrix housing. With centric retention, 10° divergence compensation, shearing force 680 g.
Details

Cutsomers also bought

Micro Retention implant 4.2/9.5 mm, sterile, (Hex Connection)
Our Micro-Retention implant is the result of persistent further development of renowned quality. Its specially conceived micro-thread helps it achieve an exceptional degree of primary stability and therefore, safety, even when the bone situation is not favourable, for example in cancellous upper jaw bones, or in the sinus area with reduced residual bone. You also have the option of working with Platform Switching here. The high precision Hex inner connection with rotation protection guarantees a secure connection between implant and abutment. Benefits: Hex connection for rotation-secure connection between implant and abutment Special micro-thread for very high primary stability Optimised thread design for improved primary stability even in soft bones Integrated Platform Switching to improve the soft tissue attachment Micro-constructed, highly pure surface for optimal cell adaptation and safe osseointegration
Details
Micro Retention implant 5.3/11.5 mm, sterile, (Hex Connection)
Our Micro-Retention implant is the result of persistent further development of renowned quality. Its specially conceived micro-thread helps it achieve an exceptional degree of primary stability and therefore, safety, even when the bone situation is not favourable, for example in cancellous upper jaw bones, or in the sinus area with reduced residual bone. You also have the option of working with Platform Switching here. The high precision Hex inner connection with rotation protection guarantees a secure connection between implant and abutment. Benefits: Hex connection for rotation-secure connection between implant and abutment Special micro-thread for very high primary stability Optimised thread design for improved primary stability even in soft bones Integrated Platform Switching to improve the soft tissue attachment Micro-constructed, highly pure surface for optimal cell adaptation and safe osseointegration
Details
Micro Retention implant 3.3/11.5 mm, sterile, (Hex Connection)
Our Micro-Retention implant is the result of persistent further development of renowned quality. Its specially conceived micro-thread helps it achieve an exceptional degree of primary stability and therefore, safety, even when the bone situation is not favourable, for example in cancellous upper jaw bones, or in the sinus area with reduced residual bone. You also have the option of working with Platform Switching here. The high precision Hex inner connection with rotation protection guarantees a secure connection between implant and abutment. Benefits: Hex connection for rotation-secure connection between implant and abutment Special micro-thread for very high primary stability Optimised thread design for improved primary stability even in soft bones Integrated Platform Switching to improve the soft tissue attachment Micro-constructed, highly pure surface for optimal cell adaptation and safe osseointegration
Details
Pro Anker matrix EM 1,
The push button anchor for secure fixing of your technical dental work in the patient’s mouth.
Details
Impression post 4.2 mm for open impression, Hex Connection incl. fixation screw short
Open Impression Technique The IMPLA impression posts are color-coded in line with the implant diameter and are equipped with a short or long fixing screw. The elongated section of the implant axis of the customized impression tray to be created must be perforated so that the fixing screw protrudes from the impression post. To secure the impression post in place, the fixing screw should be carefully hand-tightened both in the implant and on the laboratory implant using the 1.2 mm screwdriver.
Details
Gingiva former, conical 5.3 / 2 mm, sterile,
These gingiva formers were specially developed to support IMPLA Hex Connection Abutments with the new emergence profile.They have a slightly conical shape which comes about through the new emergence profile. This shape makes them especially but not exclusively well-suited for cases where the gingiva can already be formed before the final prosthetic is inserted which can support the creation of an excellent emergence profile. The gingiva formers come in sterile packaging which saves you the sterilization time before use.
Details